IMPORTANT
·
All
plumbing works must be completed and heater tank filled with water before
proceeding to electrical connections. This will prevent any damage to the
appliance.
·
Ensure
that the electrical supply is single-phase at 220 to 240 Va.c.
·
This
appliance must be permanently earthed. The use of Plug & Socket is not
recommended.
·
It
is recommended to install an approved current operated type Earth Leakage
Circuit Breaker (ELCB) or Residual Current Circuit Breaker (RCCB) of 10mA
sensitivity and higher than rated current (Refer to table).
·
It
is recommended to install an approved type Miniature Circuit Breaker (MCB) or
Molded Case Circuit Breaker (MCCB) of higher than appliance rated current
(Refer to table).
·
Ensure
that the wiring can supply the necessary amperage (Refer to table).
·
This
appliance must be permanently connected to the electrical supply through a
Double Pole Linked Switch above rated current (Refer to table) and having
contact separation of at least 3mm in all poles incorporated in the fixed
wiring. The switch must be out of reach from user in the bathroom.
·
Do
not share the electrical supply with other appliances.
|